asdasd
It is a cost effective, intelligent solar inverter which accept Solar & Utility input at the same time. The comprehensive LCD display offers user-configurable and easy-accessible button adjustment such as battery charging current, AC/solar charger priority and DC priority.When battery voltage low,it will automatically switch to AC grid to supply continuously power to the loads.
| MODEL | Xtreme Solar6+6 | Xtreme Solar 11+11 | ||||
|---|---|---|---|---|---|---|
| Nominal Battery System Voltage | 12VDC | 24VDC | ||||
| INVERTER OUTPUT | ||||||
| Rated Power | 1200VA/720W | 2400VA/1440W | ||||
| Waveform | Simulated Sine-wave | |||||
| Nominal Output Voltage RMS | 230V | |||||
| Output Voltage Regulation | +10/-18% | |||||
| Output Frequency | 50Hz/60Hz +/-1 Hz | |||||
| Inverter Efficiency(Peak) | >80% | |||||
| Line Mode Efficiency | >98% | |||||
| Typical Transfer Time | Typical 15~20ms 40ms max | |||||
| AC INPUT | ||||||
| Voltage | 230VAC | |||||
| Selectable Voltage Range | Narrow | 170~280VAC | ||||
| Selectable Voltage Range | Wide | 90~280VAC | ||||
| Frequency Range | 40Hz-70Hz (Auto sensing) | |||||
| BATTERY | ||||||
| Nominal Input Voltage | 12VDC | 24VDC | ||||
| Minimum Start Voltage | 10.5VDC | 21.0VDC | ||||
| Low Battery Alarm | 10.4VDC (min) | 20.8VDC (min) | ||||
| Low Battery Cutoff | 9.9~12VDC (Can be set) | 19.8~24VDC (Can be set) | ||||
| High Voltage Cutoff | 15.0VDC (max) | 30.0VDC (max) | ||||
| SOLAR CHARGER & AC CHARGER | ||||||
| Maximum PV Charge Current | 50A (max) | |||||
| Maximum PV Array Power | 450W/750W | 900W/1500W | ||||
| MPPT Range @ Operating Voltage | 16~55VDC | |||||
| Maximum PV Array Open Circuit Voltage | 55VDC | |||||
| Maximum Efficiency | >95% | |||||
| Standby Power Consumption | <2W | |||||
| AC Charger Voltage | 14.5(max) | 29(max) | ||||
| AC Charging Current | 10A / 20A (Can be set) | |||||
| Maximum Charge Current | 10-50A (Can be set) | |||||
| BYPASS & PROTECTION | ||||||
| Nominal Input Frequency | 40Hz – 70Hz | |||||
| Overload Protection (SMPS Load) | FUSE | |||||
| Output Short Circuit Protection | FUSE | |||||
| Bypass Fuse Rating | 10A | |||||
| Max Bypass Current | 10Amp | |||||
| MECHANICAL SPECIFICATIONS | ||||||
| Machine Dimensions (W*H*D) | 231*290*92mm | |||||
| Package Dimensions (W*H*D) | 595*375*315mm | |||||
| Net Weight (kg) | 2.8 | 4.0 | ||||
| Gross Weight (kg) | 3.5 | 4.7 | ||||
| OTHER | ||||||
| Operation Temperature Range | 0°C to 50°C | |||||
| Audible Noise | 50dB MAX | |||||
| Display | LED+LCD | |||||
| Loading(20GP/40GP/40HQ) | 1700pcs / 3400pcs / 4100pcs | |||||